SIMA User Manual SIMA System Configuration
page 10 of 63
4.4.2. Rear View
Rear panel with power supply plug and type plates.
Remark: On request there are different designs available, eg. with the power supply plug (and the type
plates) on one of the side panels.
4.4.3. SIMA Start Screen
After booting the IPC and loading the operation system the standard SimaSoft screen with the full
sized ACTUATOR OVERVIEW window is displayed (see clause 6.2, SIMA status window, p.12). This is so
in both the touch screen version and the basic version configuration with standard PC components
(monitor, keyboard).
4.4.4. Calibration of Touch Screen (only Touch version)
On delivery the SIMA integral touch screen is optimal adjusted. If necessary the touch sensitive
display can be adjusted again. For this please follow the SIMA supplement instruction “Calibration
integral Touch Screen”. You find this PDF-document and the corresponding calibration utility (exe file)
either in the windows menu (of SIMA computer) S
TART PROGRAMS TOUCHKIT or in the windows
directory C:\SIMASOFT\TOUCHKIT.
4.5. Data Communication to host (DCS)
This refers to the data exchange between the Host and the SIMA Master Station (Stand-by Station,
resp.)
4.5.1. Communication data – actuators
Process data to actuators
(Output command signals)
- OPEN
- CLOSE
- Setpoint value
Process data from actuator
(General indications)
- Running CLOSE
- Running OPEN
- Setpoint reached
- CLOSED position
- OPEN position
- TSC (DSR); Torque fault in direction CLOSE
- TSO (DOEL); Torque fault in direction OPEN
- LSC (WSR); Limit switch in direction CLOSE
- LSO (WOEL); Limit switch in direction OPEN
- Selector switch in REMOTE
- Selector switch in LOCAL
- Position feedback of actuator (0-1000 per mil)
Process data from actuator
(Fault indications)
- Fault indication
- Warning indication
- Not ready indication (only with AUMATIC actuator controls)
- Loss of phase
- Thermal fault
4.5.2. Communication data – SIMA
Process data to SIMA
(Output command signals)
- No. of slaves
- High station address
- Force scan
- Registers for simulation purposes
Process data from SIMA
(General indications)
- Live list of MASTER and STAND-BY SIMA channel A and B
- Feedback of communication status